Home » products » Weighing Inst. » Weight Transmitters » DAT 500


DAT 500

13/2013

Weighing Inst. Weight Transmitters

Weighing Inst.

Weight Transmitters





TECHNICAL CHARACTERISTICS DAT 500

Trasducer input voltage: 5 V (max 6 load cells 350  Ohm)
Measuring range: -0.5÷+3..5 mV/V (-3.9÷+3.9 mV/V optional)
Input sensitivity: 0.02 µV/ per count
Linearity: <0.01% of full scale
Gain drift: <0.001% full scale/ °C
Display: 6 digit, red LED (7 segments), h 14 mm
A/D Converter: 24 bit
Resolution: > 16.000.000 counts
Visible resolution: 60.000 divisions displayable on net weight
Divisions value (adjustable): x1, x2, x5
Set decimal: 0.0 ; 0.00 ; 0.000
Filter: 0.1 ÷ 25 Hz adjustable
Tool voltage: 24 V c.c. ±15% - power 5 W
Temperature range: -10 ÷ +50 °C
Storage temperature: -20 ÷ +70 °C
Logic output: 2 Solid-state relays, (maximum load 24 Vdc / 100 mA each)
Logic input: 2 optoisolated 24 V c.c. PNP (External voltage)
Serial door: RS232C or RS422/RS485 with ASCII or Modbus RTU protocols
Transmission distance: 15m (RS232C), 1000m (RS422 e RS485)
Peak Hold function: for dynamic measures
Baud rate: 2400, 9600, 19200, 38400, 115200 adjustable
Regulatory compliance: EN61326-1, EN55011 and EN55014 for EMC; EN61010-1 for electrical security
Electrical connection: Terminal screw pass 5 mm
Dimensions and weight: 96 x 48 x 120 mm (L x H x D); 250 g
Bipolar optional output: only in voltage ±10V

Accessories are not to be considered included in the price of each product.
All the above is purely illustrative and not to be understood demanding towardsPrecise Instrument Corporation