Home » products » Weighing Inst. » Atex and Stainless Steel » DAT S 400 (ATEX 2,22)
Weighing Inst.
Atex and Stainless Steel
Trasducer voltage: | 5 V (max 6 load cells 350 Ohm) |
Measuring range: | -0.5 ÷ +3.5 mV/V (optional -3.9 ÷ +3.9 mV/V) |
Offset, drift: | 0.02 microV/°C |
Linearity: | <0.01% of full scale |
Gain drift: | <0.001% full scale/ °C |
LED status: | 4 red |
D/A convertitor: | 24 bit |
Displayable resolution: | 60.000 divisions displayable on net weight |
Set decimal: | 0.0 ; 0.00 ; 0.000 |
Filter: | adjustable 0.1 ÷ 25 Hz |
Tool voltage: | 24 V c.c. ±15% - power 5 W |
Temperature range: | -10/+40 °C |
Storage Temperature: | -20/+50°C |
Logic output: | 2 relays (clean contact) MAX 24 V c.c./100 mA cad. |
Logic input: | 2 optoisolated 24 V c.c. PNP (External voltage) |
Serial door: | USB, RS232C o RS422/RS485 with ASCII or Modbus RTU protocols |
Trasmission distance: | 15m (RS232C), 1000m (RS422 e RS485) |
Others fieldbus comunication: | CANopen, Modbus-Plus and other |
Peak Hold function: | for dynamic measures |
Baud rate: | 2400, 9600, 19200, 38400, 115200 adjustable |
Regulatory compliance: | EN61326-1, EN55011 and EN55014 for EMC; EN61010-1 for electrical security |
ATEX II 3 GD EEx nR IIC IP65 T6: | EN 13463-1: 2003; EN 60529: 1991 + A1: 2000 IEC 60079-0: 2004; IEC 60079-15: 2005 |
Analogic output (optional): | Optoisolated 16 bit, Tension:0÷5 or 0÷10V (R >10 K Ohm), Current: 0÷20 o 4÷20mA (R < 300 Ohm), Linearity: 0,03 of full scale |
BCD optional output: | via external modules |
FIELDBUS optional protocol: | PROFIBUS, DEVICENET |
AC power supply: | 115 / 230 Vdc 50/60 Hz |