Home » products » Load Cells » Compression » 220
 
    Load Cells
Compression
 
    		




| Rated load (R.L.): | 5000, 10000, 20000, 30000, 50000*** kg | 
| NTEP/OIML Accuracy class: | NTEP, OIML C3 | 
| Maximum no. of intervals (n): | 3000 | 
| Y = Emax/Vmin: | 14000 | 
| Rated output (R.O.): | 2.0 mV/V | 
| Repeatability: | 0.1% of R.O. | 
| Zero balance: | 2% of R.O. | 
| Creep (30 minutes): | 0.0170 +/-% of applied load | 
| Combined error: | 0.0200 % of R.O. | 
| Temp. effect (-10° to +50°C) on zero balance: | 0.0010 % of R.O./°C | 
| Temp. effect (-10°C to +50°C) on output: | 0.0010 % of applied load/°C | 
| Compensated temperature Range: | -10 ÷ +40 °C | 
| Temperature range: | -30 ÷ +70 °C | 
| Safe overload: | 150% of R.L. | 
| Maximum overload: | 300% of R.L. | 
| Recommended input: | 10 Vdc/Vac | 
| Maximum excitation: | 20 Vdc/Vac | 
| Input resistance: | 1065 ± 60 Ohm | 
| Output resistance: | 1025 ± 20 Ohm | 
| Insulation resistance: | >2000 M Ohm | 
| Cable length: | 5m (5T), 10m (10 & 20T), 20m (30 & 50T) | 
| Cable type: | 6 wires, braided, Polyurethane, double floating screen Standard | 
| Material: | Stainless steel | 
| Degree of protection: | IP68 |