Home » products » Load Cells » S-Types » TRP


TRP

29/2014

Load Cells S-Types

Load Cells

S-Types




  • Capacity 2 - 50 kg
  • Protection IP65
  • Overload capability greater than 300%
  • Made of stainless steel

TECHNICAL CHARACTERISTICS TRP

Rated load (R.L.): 2÷50 kg
Rated output (R.O.): 2.0 mV/V ± 0.1%
Temperature effect on zero balance: ±0.005% R.O./°C
Temperature effect on output: ±0.005% on output/°C
Combined error: ±0.05% of R.O.
Repeatability: ±0.02% of R.O.
Creep (20 minutes): ±0.03% of R.O.
Input resistance: 350 ± 20 Ohm
Output resistance: 350 ± 5 Ohm
Insulation resistance: > 5000 M Ohm
Recommended input: 2÷15 Vcc/ca
Temperature range: -20 / +70°C
Compensated temperature range: -10 / +50°C
Safe overload: 150% of R.L.
Ultimate overload: > 300% of R.L.
Degrees of protection: IP65
Deflection: 0.4 mm
Ultimate sideload: 300% of R.L.
Material: Stainless steel 17-4PH (Avional 2kg)

Accessories are not to be considered included in the price of each product.
All the above is purely illustrative and not to be understood demanding towardsPrecise Instrument Corporation