Home » products » Web Tension Systems BLH NOBEL » Off Center » KIP-1
Web Tension Systems BLH NOBEL
Off Center
Rated load (R.L.): | 10, 20 kN |
Combined error (terminal): | ± 0.1 % of R.O. |
Repeatability: | 0.02 % of R.O. |
Safe overload: | 100* % of R.L. |
Ultimate overload: | 200* % of R.L. |
Recommended input: | 10 V DC or AC |
Input voltage maximum: | 18 V DC or AC |
Input resistance: | 382 ± 3 Ohm |
Output resistance: | 350 ± 3 Ohm |
Rated output (R.O.): | 1.020 mV/V |
Tolerance of R.O.: | ± 0.25 |
Zero balance: | ± 2 % of R.O. |
Temperature range: | - 40 to + 80 (+ 100)** °C |
Temperature effect (-10°C to +50°C) On output: | ± 0.005 % of output/ °C |
Temperature effect (-10°C to +50°C) On Zero balance: | ± 0.005 % of R.O./ °C |
Insulation resistance at 200 V DC: | >4 G Ohm |
Material: | Stainless steel |
Electrical connection: | 5 m shielded four conductor cable |
Degree of protection: | IP 67 |
*For load perpendicular to the transducer **- 40 to + 100°C on demand |