Home » products » Weighing Inst. » Atex and Stainless Steel » E 70/2
Weighing Inst.
Atex and Stainless Steel
Transducer power supply: | max 5 V (max 6 cells of 350 Ohms) through intrinsic safety barriers |
Measuring range: | from transducers with sensitivity from -3.9 to +3.9 mV / V |
Input sensitivity: | 0.02 micronV/division |
Linearity: | <0.01% of full scale |
Thermal drift | <0.0003% of full scale / ° C |
Display: | 7 digit, 7-segment red LED, height 14mm |
A/D converter: | 24 bits |
Internal resolution: | > of 16,000,000 points |
Viewable resolution: | 60,000 displayable divisions on the net weight |
Settable decimals: | 0.0; 0.00; 0.000 |
Filter: | selectable from 0.2 to 50 Hz |
Keyboard: | 14 buttons in ATEX execution |
Power supply: | 230 Vdc 50/60 Hz (optional 115 Vdc) max absorption 15VA |
Temperature range: | -10 To +50 ° C (max 85% humidity non-condensing) |
Storage temperature: | -20 ÷ +70 °C |
Logic outputs: | 6 relays (contact) MAX 115Vac/30 Vdc, 0.5 A each |
Logic inputs: | 6 opto-isolated 12 V cc PNP |
Serial port: | RS232C or RS422/RS485 |
Transmission distance: | 15m (RS232C), 100m (RS422 and RS485) |
Standard protocol: | ASCII, MODBUS RTU |
Baud rate: | 1200, 2400, 4800, 9600, 19200, 38400, 115200 selectable |
Regulatory Compliance: | EN50081-1, EN5002-2 for EMC; |
EN61010-1 for Electrical Safety | |
94/9/EC for ATEX II 2 GD; EEx d IIB T6÷T4 |