Home » products » Weighing Inst. » Atex and Stainless Steel » E 90/1
Weighing Inst.
Atex and Stainless Steel
Transducer power supply: | max 5 V (max 6 cells of 350 Ohms) through intrinsic safety barriers |
Measuring range: | from transducers with sensitivity from 0.5 to +3.5 mV/V |
Input sensitivity: | 0.02 micronV/division |
Linearity: | <0.01% of full scale |
Thermal drift: | <0.001% of full scale /°C |
A/D converter: | 24 bits |
VIewable resolution: | 60.000 displayable divisions on the net weight |
Settable decimals: | 0.0; 0.00; 0.000 |
Filter: | selectable from 0.1 to 25 Hz |
Keyboard: | 4 buttons running EX |
Power supply: | 24 VDC ± 15% - power consumption 5W or 115/230 Vac with integrated power supply |
Temperature range: | -10 To +50 ° C (max 85% humidity non-condensing) |
Storage temperature: | -20 ÷ +70 °C |
Logic outputs: | 2 relays (contact) MAX 24 Vcc/100 mA cad |
Logic inputs: | 2 opto-isolated 24 Vcc PNP (external power supply) |
Serial port: | RS232C or RS422/RS485 |
Transmission distance: | 15m (RS232C), 100m (RS422 and RS485) |
Standard protocol: | ASCII, MODBUS RTU |
Peak Hold Function | for dynamic measurements |
Baud rate: | 2400, 9600, 19200, 38400, 115200 selectable |
Regulatory compliance: | EN50081-1, EN5002-2 for EMC; |
EN61010-1 for Electrical Safety | |
94/9/EC for ATEX II 2 GD; EEx d IIB T6÷T4 | |
Manual batching: | a single component in loading or unloading |
Fieldbus connection option: | Profibus-DP with integrated board |
Analog output: | 16-bit |
Voltage: 0 to 10 V and 0 to 5 V (R min 10k Ohms) | |
Power: 0 to 20 mA, 4 to 20 mA (R max 300 Ohms) |