Home » products » Load Cells » Off Center » 1260
 
    Load Cells
Off Center





| Rated capacity—R.C. (Emax): | 50, 75, 100, 150, 250, 300, 500, 635kg | 
| Rated output (R.O.): | 2.0 mV/V | 
| Zero balance: | 0.2 ±mV/V | 
| Creep (30 min.): | 0.0170 ±% of applied load | 
| Total error: | 0.0200 ±% of rated output | 
| Temperature effect on zero: | 0.0023 ±% of rated output/°C | 
| Temperature effect on output | 0.0010 ±% of applied load/°C | 
| Temperature range, compensated: | –10 to +40 °C | 
| Temperature range, safe: | –20 to +70 °C | 
| Maximum safe central overload: | 150 % of R.C. | 
| Ultimate central overload: | 300 % of R.C. | 
| Excitation, recommended: | 10 VDC or VAC RMS | 
| Excitation, maximum: | 15 VDC or VAC RMS | 
| Input impedance: | 415±15 Ohms | 
| Output impedance: | 350±3 Ohms | 
| Insulation resistance: | >2000 MOhms | 
| Cable length: | 3mt | 
| Cable type: | 6-wire, braided, polyurethane, dual floating screen | 
| Environmental protection: | IP66 | 
| Platform size (max): | 600 x 600 mm | 