Home » products » Load Cells » Off Center » 1320


1320

39/2014

Load Cells Off Center

Load Cells

Off Center





TECHNICAL CHARACTERISTICS 1320

Rated capacity—R.C. (Emax): 1000, 1500, 2000 kg
Maximum no. of intervals (n): 3000
Rated output—R.O.: 2.0 mV/V
Rated output tolerance: 0.2 ±mV/V
Zero balance: 0.2 ±mV/V
Zero return, 30 min: 0.0170 ±% of applied load
Total error: 0.0200 ±% of rated output
Temperature effect on zero: 0.0023 ±% of rated output/°C
Temperature effect on output: 0.0010 ±% of applied load/°C
Temperature range, compensated: –10 to +40 °C
Temperature range, safe: -30 to +70 °C
Maximum safe central overload: 150 % of R.C.
Ultimate central overload: 300 % of R.C.
Excitation, recommended: 10 VDC or VAC RMS
Excitation, maximum: 15 VDC or VAC RMS
Input impedance: 415±15 Ohms
Output impedance: 350±3 Ohms
Insulation resistance: >2000 MOhms
Cable length: 5 m
Applications: Very large platform scales; Crane Scales; Check weighing

Accessories are not to be considered included in the price of each product.
All the above is purely illustrative and not to be understood demanding towardsPrecise Instrument Corporation