Home » products » Load Cells » Off Center » 1320
Load Cells
Off Center
Rated capacity—R.C. (Emax): | 1000, 1500, 2000 kg |
Maximum no. of intervals (n): | 3000 |
Rated output—R.O.: | 2.0 mV/V |
Rated output tolerance: | 0.2 ±mV/V |
Zero balance: | 0.2 ±mV/V |
Zero return, 30 min: | 0.0170 ±% of applied load |
Total error: | 0.0200 ±% of rated output |
Temperature effect on zero: | 0.0023 ±% of rated output/°C |
Temperature effect on output: | 0.0010 ±% of applied load/°C |
Temperature range, compensated: | –10 to +40 °C |
Temperature range, safe: | -30 to +70 °C |
Maximum safe central overload: | 150 % of R.C. |
Ultimate central overload: | 300 % of R.C. |
Excitation, recommended: | 10 VDC or VAC RMS |
Excitation, maximum: | 15 VDC or VAC RMS |
Input impedance: | 415±15 Ohms |
Output impedance: | 350±3 Ohms |
Insulation resistance: | >2000 MOhms |
Cable length: | 5 m |
Applications: | Very large platform scales; Crane Scales; Check weighing |