Home » products » Load Cells » Off Center » 1320
 
    Load Cells
Off Center
 
    		




| Rated capacity—R.C. (Emax): | 1000, 1500, 2000 kg | 
| Maximum no. of intervals (n): | 3000 | 
| Rated output—R.O.: | 2.0 mV/V | 
| Rated output tolerance: | 0.2 ±mV/V | 
| Zero balance: | 0.2 ±mV/V | 
| Zero return, 30 min: | 0.0170 ±% of applied load | 
| Total error: | 0.0200 ±% of rated output | 
| Temperature effect on zero: | 0.0023 ±% of rated output/°C | 
| Temperature effect on output: | 0.0010 ±% of applied load/°C | 
| Temperature range, compensated: | –10 to +40 °C | 
| Temperature range, safe: | -30 to +70 °C | 
| Maximum safe central overload: | 150 % of R.C. | 
| Ultimate central overload: | 300 % of R.C. | 
| Excitation, recommended: | 10 VDC or VAC RMS | 
| Excitation, maximum: | 15 VDC or VAC RMS | 
| Input impedance: | 415±15 Ohms | 
| Output impedance: | 350±3 Ohms | 
| Insulation resistance: | >2000 MOhms | 
| Cable length: | 5 m | 
| Applications: | Very large platform scales; Crane Scales; Check weighing |