Home » products » Load Cells » BLH Nobel » KIS-3
Load Cells
BLH Nobel
Rated load (R.L.): | 1, 2, 5, 10, 20 kN |
Combined error: | ±0.02% of R.O. |
Repeatability: | ±0.01% of R.O. |
Safe overload: | 200*% of R.L. |
Ultimate overload: | 300*% of R.L. |
Safe uplift: | 100% of R.L. |
Ultimate uplift: | 120% of R.L. |
Safe sideload: | 100*% of R.L. |
Ultimate sideload: | 200*% of R.L. |
Recommended input: | 5 V DC or AC |
Input voltage maximum: | 18 V DC or AC |
Input resistance: | 350 ± 3 Ohms |
Output resistance: | 350 ± 0.5 Ohms |
Rated output (R.O.): | 2.040 mV/V ±0.1% |
Zero balance: | ±1% of R.O. |
Creep (30 minutes): | ±0.01% of R.L. |
Temperature range: | -40 ÷ +105 °C*** |
Temp. effect (-10°C to +50°C) (14 to 120°F) On output: | ±0.001% of output/°C |
Insulation resistance at 200V DC: | > 4 G Ohms |
Material (load cell): | Stainless steel |
Material (accessories): | Yellow chromate steel or stainless steel |
Electrical connection: | 4 conductors shielded cable; length 5 m |
Degree of protection: | IP67 |
ATEX/FM/CSA | Certified versions for use in explosive atmospheres are available |
ATEX: | II 1 GD EEx ia |
IIC T4 Tamb = 40 °C EEx ia | |
IIC T6 Tamb = 60 °C | |
FM: | 3611 (Classes I, II, III; Div 1,2; Group A-G) |
CSA: | C22.2 (Classes I, II, III; Div 1, 2; Group A-G) |
* With reference to the loading point recommended | |
*** On demand |