Applications:
 
    		

| Rated load (R.L.): | 1, 2, 5, 10, 20, 50, 100, 200 kN | 
| Combined error: | ±0.075% of R.O. | 
| Repeatability: | ±0.02% of R.O. | 
| Safe overload: | 50% of R.L.* | 
| Ultimate overload: | 100% of R.L.* | 
| Ultimate sideload: | 100% of R.L.* | 
| Recommended input: | 5 Vdc or Vac | 
| Input voltage maximum: | 18 Vdc or Vac | 
| Input resistance: | 350 ± 5 Ohms | 
| Output resistance: | 350 ± 0.5 Ohms | 
| Rated output (R.O.): | 2.040 mV/V ±0.25% | 
| Zero balance: | ±2% of R.O. | 
| Tolerance of shunt calibration values: | ±0.25% of value** | 
| Creep (30 minutes): | ±0.03% of R.L. | 
| Temperature range: | - 40 ÷ + 80 (+ 100) °C *** | 
| Temp. effect (-10°C to +50°C) (14 to 120°F) On output: | ±0.003% of output/°C | 
| Temp. effect (-10°C to +50°C) (14 to 120°F) On Zero balance: | ±0.003% of R.O./°C | 
| Insulation resistance at 200V DC: | > 4 G Ohms | 
| Material (load cell): | Stainless steel | 
| Electrical connection: | 5 m shielded four conductor cable 1, 2, 5, 10, 20 kN | 
| 10 m shielded cable with four conductors 50, 100, 200 kN | |
| Degree of protection: | IP67 | 
| ATEX certified versions available for use in hazardous areas are available II 1GD | |
| * With reference to the loading point recommended | |
| ** See the calibration chart of the load cell | |
| *** On demand -40° ÷ +100°C |