Home » products » Load Cells » BLH Nobel » KIS-11
Load Cells
BLH Nobel
Applications:
Rated load (R.L.): | 50 kN |
Combined error: | ±0.02% of R.O. |
Repeatability: | 0.01% of R.O. |
Safe overload: | 100*% of R.L. |
Ultimate overload: | 200*% of R.L. |
Safe sideload: | 100*% of R.L. |
Ultimate sideload: | 200*% of R.L. |
Recommended input: | 5 V DC or AC |
Input voltage maximum: | 18 V DC or AC |
Input resistance: | 350 ± 3 Ohms |
Output resistance: | 350 ± 0.5 Ohms |
Rated output (R.O.): | 1.020 mV/V ±0.1% |
Zero balance: | ±1% of R.O. |
Creep (30 minutes): | ±0.04% of R.L. |
Temperature range: | -40 ÷ +80 (+100)*** °C |
Temp. effect (-10°C to +50°C) (14 to 120°F) on output: | ±0.0010% on output/°C |
Temp. effect (-10°C to +50°C) (14 to 120°F) On Zero balance: | ±0.0014% of R.O./°C |
Insulation resistance at 200 V DC: | > 4 G Ohms |
Material (load cell): | Stainless steel |
Material (accessories): | Yellow chromate steel**** |
Electrical connection: | 10m shielded four conductor cable |
Degree of protection: | IP67 |
ATEX certified versions for use in explosive atmospheres are available: II 1GD | |
* Referring to recommended loading case | |
*** -40° ÷ +100°C on demand | |
**** Stainless steel on demand | |
Approved in accordance with international recommendations OIML R 60 1991 edition, C3. |