Home » products » Load Cells » Off Center » PSTA2


PSTA2

37/2014

Load Cells Off Center

Load Cells

Off Center





TECHNICAL CHARACTERISTICS PSTA2

Rated load (RL): 6 - 10 - 15 - 20 - 25 - 30 - 35 - 40 Kg
Combined error: ±0,02 %FS
Creep (30 min): ±0,02 %FS
Load limit: 150 %FS
Breaking load: 300 %FS
Power supply: Vcc 15 Max
Output signal: 2 mV/V
Input resistance: 380-386 Ohm
Output resistance: 350-351 Ohm
Insulation resistance: > 2000 M Ohm
Operation temperature: -20 ÷ +70 °C
Compensated temperature: -10 ÷ +50 °C
Zero thermal drift: ±0,003 %FS/°C
FS thermal drift: ±0,002 % FS/°C
Protection level: IP67
Material: INOX steel Aisi 431
Shielded cable: Length 6m

Accessories are not to be considered included in the price of each product.
All the above is purely illustrative and not to be understood demanding towardsPrecise Instrument Corporation