Home » products » Load Cells » Double-Ended Shear Beam » 460
 
    Load Cells
Double-Ended Shear Beam
 
    		


| Rated load (R.L.): | 3 ton (NO OIML), 5, 10, 20, 30, 50, 75, 100 ton | 
| Combined error: | < ±0.017% of R.O. | 
| Repeatability: | < ±0.015% of R.O. | 
| Creep (20 minutes): | < ±0.016% of R.L. | 
| Safe overload: | 150% of R.L. | 
| Ultimate overload: | 200% of R.L. | 
| Recommended input: | 5÷15 Vdc/Vac | 
| Input resistance: | 800 ± 20 Ohm | 
| Output resistance: | 700 ± 3 Ohm | 
| Insulation resistance: | > 5000 M Ohm | 
| Rated output (R.O.): | 2 ± 0.1% mV/V | 
| Zero balance: | < ±2% of R.O. | 
| Temperature range: | -30 ÷ +70 °C | 
| Compensated temperature range: | -10 ÷ +40 °C | 
| Temperature effect on zero balance: | < ±0.010% of R.O./5°K | 
| Temperature effect on output: | < ±0.006% on output/5°K | 
| Max load deflection: | 0.6÷1 mm | 
| Precision class: | 3000 n. OIML | 
| Degree of protection: | IP68 | 
| Electrical connection: | 6 conductors shielded cable; length 12 m | 