Home » products » Load Cells » BLH Nobel » KIMD-1
Load Cells
BLH Nobel
Rated load (R.L.): | 500, 800 kN |
Combined error: | ±0.1% of R.O. |
Repeatability: | 0.02% of R.O. |
Safe overload: | 50% of R.L.* |
Ultimate overload: | 100% of R.L.* |
Recommended input: | 10 Vdc/ac |
Input voltage maximum: | 18 Vdc/ac |
Input resistance: | 350 ± 5 Ohm |
Output resistance: | 350 ± 0.5 Ohm |
Rated output (R.O.): | 2.040 mV/V ±0.25% |
Zero balance: | ±2% of R.O. |
Tolerance of shunt calibration values: | ±0.25% of value** |
Creep (30 minutes): | ±0.03% of R.L. |
Temperature range: | -40 / +80 (+100)*** |
Temperature effect (-10°C to +50°C) (14 to 120°F) On output: | ±0.003% of output/°C |
Temperature effect (-10°C to +50°C) (14 to 120°F) On Zero balance: | ±0.003% of R.O./°C |
Insulation resistance at 200 V DC: | > 4 G Ohm |
Material: | Yellow chromate steel |
Electrical connection: | 10 m shielded four conductor cable |
Degree of protection: | IP67 |
ATEX certified versions for use in explosive atmospheres are available. II 1GD EEx ia IIC T4 Tamb = 60°C | |
* With reference to the loading point recommended | |
** See the calibration chart of the load cell | |
*** -40° ÷ +100°C on demand |