Home » products » Load Cells » BLH Nobel » KOSD40
Load Cells
BLH Nobel
Applications:
Rated load (R.L.): | 10, 20, 50, 100, 200 kN |
Combined error: | ±0.5% of R.O. |
Repeatability: | 0.25% of R.O. |
Safe overload: | 100*% of R.L. |
Ultimate overload: | 200% of R.L. |
Safe sideload: | 100% of R.L. |
Ultimate sideload: | 200% of R.L. |
Recommended input: | 10 Vdc/ac |
Input voltage maximum: | 18 Vdc/ac |
Input resistance: | 350 ± 5 Ohm |
Output resistance: | 350 ± 5 Ohm |
Rated output (R.O.): | about 1 mV/V |
Zero balance: | ±5% of R.O. |
Tolerance of shunt calibration values: | ±1% of value** |
Temperature range: | -40 to +80 (+100)°C*** |
Temp. effect on output (-10° ÷ +50°C): | ±0.04% of output/°C |
Temp. effect on zero balance (-10° ÷ +50°C): | ±0.04% of R.O./°C |
Insulation resistance at 200 V DC: | > 4 G Ohm |
Material: | Stainless steel |
Electrical connection: | 5m shielded four conductor cable 10, 20, 50kN 10m shielded four conductor cable 100, 200kN |
Degree of protection: | IP67 |
* Referring to recommended loading point | |
** See the calibration chart of the load cell | |
*** -40° ÷ +100°C on demand | |
ATEX certified versions available for use in hazardous areas. II 1GD EEx ia IIC T4 Tamb = 60 ° C |