Home » products » Load Cells » Double-Ended Shear Beam » MASTERMOUNT
Severity: Warning
Message: Undefined property: stdClass::$SchedaTecnica
Filename: views/dettaglio_prodotto.php
Line Number: 40
Load Cells
Double-Ended Shear Beam
Severity: Warning
Message: Undefined property: stdClass::$SchedaTecnica
Filename: views/dettaglio_prodotto.php
Line Number: 59


| Rated load (R.L.): | 2, 5, 10, 15, 20, 30 t |
| Rated Output (R.O.): | 2.0(±0.25%) mV/V |
| Recommended input: | 10 V |
| Input voltage maximum: | 18 V |
| Safe overload: | 150% of R.L. |
| Ultimate overload: | 300 % of R.L. |
| Safe sideload: | 30% R.L. |
| Ultimate sideload: | 100% of R.L. |
| Combined Error: | < ±0.03 % R.O. |
| Repeatability: | < ±0.015 % R.O. |
| Input resistance: | 785 ± 20 Ohm |
| Output resistance: | 700 ± 5 Ohm |
| Temperature range: | -50 to +80 °C |
| Compensated temperature range: | -10 to +40 °C |
| Temperature effect on zero balance: | < ±0.002% SN/°C |
| Temperature effect on output: | < ±0.0012% of output/°C |
| Electrical connection: | 4 conductors, shielded polyurethane cable; L= 20m |
| Insulation resistance: | > 500 M Ohm @ 100 Vdc |