Home » products » Load Cells » Pin » PRX
Load Cells
Pin

| Rated load (R.L.): | 5, 10, 20, 40, 60, 80, 100 t |
| Combined error: | < ±0.1% of R.O. |
| Repeatability: | < ±0.02% of R.O. |
| Creep (20 minutes): | < ± 0.03% of R.O. |
| Safe overload: | 150% of R.L. |
| Ultimate overload: | 300% of R.L. |
| Recommended input: | 5÷15 Vcc/ca |
| Input resistance: | 350 ± 20 Ohms |
| Output resistance: | 350 ± 5 Ohm |
| Insulation resistance: | > 5000 M Ohms |
| Rated output (R.O.): | 1 ± 0.1% mV/V |
| Zero balance: | < ±2% of R.O. |
| Temperature range: | -20 ÷ +70 °C |
| Compensated temperature range: | -10 ÷ +50 °C |
| Temperature effect on zero balance: | < ±0.005% R.O./°C |
| Temperature effect on output: | < ±0.005% on output/°C |
| Deflection: | 0.4mm |
| Degree of protection: | IP68 |
| Material: | Stainless steel |
| Electrical connection: | 6 conductors shielded cable; lenght 5 m |