Home » products » Load Cells » Pin » PRX
 
    Load Cells
Pin
 
    		
| Rated load (R.L.): | 5, 10, 20, 40, 60, 80, 100 t | 
| Combined error: | < ±0.1% of R.O. | 
| Repeatability: | < ±0.02% of R.O. | 
| Creep (20 minutes): | < ± 0.03% of R.O. | 
| Safe overload: | 150% of R.L. | 
| Ultimate overload: | 300% of R.L. | 
| Recommended input: | 5÷15 Vcc/ca | 
| Input resistance: | 350 ± 20 Ohms | 
| Output resistance: | 350 ± 5 Ohm | 
| Insulation resistance: | > 5000 M Ohms | 
| Rated output (R.O.): | 1 ± 0.1% mV/V | 
| Zero balance: | < ±2% of R.O. | 
| Temperature range: | -20 ÷ +70 °C | 
| Compensated temperature range: | -10 ÷ +50 °C | 
| Temperature effect on zero balance: | < ±0.005% R.O./°C | 
| Temperature effect on output: | < ±0.005% on output/°C | 
| Deflection: | 0.4mm | 
| Degree of protection: | IP68 | 
| Material: | Stainless steel | 
| Electrical connection: | 6 conductors shielded cable; lenght 5 m | 