Home » products » Load Cells » Bending beam » 300 i
 
    Load Cells
Bending beam
 
    		


| Rated load (R.L.): | 5, 10, 20, 30, 50, 75, 100, 150, 200, 250, 300, 500 Kg | 
| Combined error: | < ±0.017% of R.O. | 
| Repeatability: | < ±0.015% of R.O. | 
| Creep (20 minutes): | < ±0.016% of R.L. | 
| Safe overload: | 150% of R.L. | 
| Maximum overload: | 200% of R.L. | 
| Recommended input: | 5÷15 Vdc/Vac | 
| Input resistance: | 400 ± 20 Ohm | 
| Output resistance: | 400 ±20 Ohm | 
| Insulation resistance: | > 5000 M Ohm | 
| Rated output (R.O.): | 2 ± 0.1% mV/V (1) | 
| Zero balance: | < ± 2% of R.O. | 
| Temperature range: | -20 ÷ +50°C | 
| Compensated Temperature Range: | -10 ÷ +40°C | 
| Temperature effect on zero balance: | < ±0.01% of R.O./5°K | 
| Temperature effect on output: | < ±0.006% of output/5°K | 
| Max load deflection: | 0.2÷0.4 mm | 
| Accuracy class: | 3000 n. OIML | 
| Degree of protection: | IP68 | 
| Electrical connection: | 4 conductors shielded cable; length 3 m | 
| (1) R.L. <= 20 kg: 2 ± 0,2% | 