Home » products » Load Cells » Universal » CS20
Load Cells
Universal
Rated load (R.L.): | 25, 50, 100, 150, 200, 250, 300, 500, 600, 750, 1000 Kg 1.5, 2, 2.5, 3, 5, 7.5, 10, 15, 20, 30 t |
Combined error: | < ±0.02% of R.O. |
Repeatability: | < ±0.01% of R.O. |
Creep (30 minutes): | ±0.02% of R.L. |
Safe overload: | 150% of R.L. |
Maximum overload: | 300% of R.L. |
Recommended input: | 5÷12 Vdc/Vac |
Input resistance: | 350 ± 3.5 Ohm |
Output resistance: | 351 ± 2.0 Ohm |
Insulation resistance: | > 5000 M Ohm |
Rated output (R.O.): | 2 ± 0.004% mV/V |
Zero balance: | < ±1.5% of R.O. |
Temperature range: | -35 ÷ +65 °C |
Compensated temperature range: | -10 ÷ +40 °C |
Temperature effect on zero balance: | < ±0.01% of R.O. /5°K |
Temperature effect on output: | < ±0.006% on output/5°K |
Max load deflection: | 0.2÷0.4 mm |
Degree of protection: | IP67 |
Material: | Nickel steel |
Electrical connection: | 4 conductors shielded cable; length 3 m; 6 m |
Precision class: | 3000 n. OIML only for carrying capacity from 100 to 2500kg |
ATEX certified version: | II1G Ex ia II1C T4; II1D Ex iaD20T73°C; II3G nL ia II C T4 |